Albright International

SW82

NO - DP - ST

The SW82 type of contactors has been designed for direct current loads, including motors as used on electric vehicles such as industrial trucks.  Developed for both interrupted and uninterrupted loads, the SW82 is suitable for switching Resistive, Capacitive and Inductive loads.

The SW82 features double pole double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity.  The contactors are compact in size and are fully serviceable with a full range of spare parts available.  The SW82 has M8 stud main terminals and 6.3mm spade coil connections.  It can be mounted via M4 tapped holes or mounting brackets – either supplied fitted, or as separate items.  Mounting can be horizontal or vertical, when vertical the M8 contact studs should point upwards. If the requirement is for downwards orientation we can adjust the contactor to compensate for this.

Show product Options or make an enquiry.
The SW82 has the following optional components available :

Enquire about product

This is largely an automated form that outputs things based on the product where it's displayed, do not touch
  • Make an enquiry

  • Name
  • Company
  • Contact number
  • Email address
  • Your message

Technical Information

Application Interrupted Uninterrupted
Thermal Current Rating 100A 100A
Intermittent Current Rating:
30% Duty 185A 185A
40% Duty 160A 160A
50% Duty 140A 140A
60% Duty 130A 130A
70% Duty 120A 120A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*)
Blowouts -
No Blowouts 800A at 80V D.C.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts 150A at 96V D.C.
Maximum Recommended Contact Voltages
Blowouts - -
No Blowouts 96V 96V
Typical Voltage Drop per pole across New Contacts at 100A 50mV
Mechanical M.T.B.F >5000000 Operations
Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V

Features

Coil Suppression
Suppression---Diode
DIODE
Suppression---Resistor-and-Diode
DIODE AND RESISTOR
Suppression---Bi-Directional-Diode
BI-DIRECTIONAL DIODE
Coil Terminations
Coil Termination - Standard
AMP TAGS
Coil Termination - Flying Leads
FLYING LEADS
Coil Termination - Vaccum Impreg
VACCUM IMPREGNATION

Downloads

Resources
SW82 and SW822 Spares Download
SW82 Catalogue Data Sheet Download
+44 (0) 1256 893060