The SW82P features double pole double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The SW82P is compact in size and features an enclosed top cover and offers environmental protection to IP66.  The SW82P has M8 stud main terminals and 6.3mm spade coil connections.  Mounted using supplied brackets, mounting can be horizontal or vertical, when vertical the M8 contact studs should point upwards.  If the requirement is for downwards orientation we can adjust the contactor to compensate for this.

SW82P Technical Information

Application
InterruptedRating ( Ith )Uninterrupted
Thermal Current Rating 100A 100A
Intermittent Current Rating:
30% Duty 185A 185A
40% Duty 160A 160A
50% Duty 140A 140A
60% Duty 130A 130A
70% Duty 120A 120A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*)
Blowouts -
No Blowouts 800A at 80V D.C.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts 150A at 96V D.C.
Maximum Recommended Contact Voltages
Blowouts - -
No Blowouts 96V 96V
Typical Voltage Drop per pole across New Contacts at 100A 50mV

Mechanical Durability > 5,000,000 Cycles
Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V

SW82P Features

Component Configurations
Coil Suppression
DIODE
DIODE AND RESISTOR
BI-DIRECTIONAL DIODE
Coil Terminations
AMP TAGS

%s Resources

SW82P Data Sheet

  • Format: .pdf
  • Size: 879kb

  • Name
  • Company
  • Contact number
  • Email address
  • Your message
  • The SW82P has the following optional components available: