Albright International

DC182P

MOTOR REVERSING - IP67

The DC182P motor reversing type of contactor has been designed for direct current loads, particularly motors as used on electric winches. The DC182P is a monoblock construction, resulting in a neat compact design which is compatible with modern electronic control systems. The DC182P is suitable for switching Resistive and Inductive loads and is sealed to IP67.

The main contact circuit, designed for motor reversing, has a built in failsafe, so that if both coils are energised simultaneously the circuit remains open.  The DC182P has double breaking main contacts with silver alloy contact tips, which are weld resistant, hard wearing and have excellent conductivity.  The DC182P M8 main stud terminals can be configured in a variety of ways in order to suit the application.  Coil connections are by means of 6.3mm spades and mounting is via the supplied bracket and can be horizontal or vertical.  When vertical the M8 contact studs should point upwards.  If the requirement is for downwards orientation we can adjust the contactor to compensate for this.

Show product Options or make an enquiry.
The DC182P has the following optional components available :

Enquire about product

This is largely an automated form that outputs things based on the product where it's displayed, do not touch
  • Make an enquiry

  • Name
  • Company
  • Contact number
  • Email address
  • Your message

Technical Information

Application Interrupted Uninterrupted
Thermal Current Rating 150A 150A
Intermittent Current Rating:
30% Duty 275A 275A
40% Duty 235A 235A
50% Duty 210A 210A
60% Duty 195A 195A
70% Duty 180A 180A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*)
Blowouts -
No Blowouts 1000A at 48V D.C.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts -
Maximum Recommended Contact Voltages
Blowouts - -
No Blowouts 48V 48V
Typical Voltage Drop per pole across New Contacts at 150A 40mV
Mechanical M.T.B.F >5000000 Operations
Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V

Features

Coil Suppression
Suppression---Diode
DIODE
Suppression---Resistor-and-Diode
DIODE AND RESISTOR
Suppression---Bi-Directional-Diode
BI-DIRECTIONAL DIODE
Coil Terminations
Coil Termination - Standard
AMP TAGS

Downloads

Resources
DC182P Catalogue Data Sheet Download
+44 (0) 1256 893060
UK Business Hours
Mon - Thu: 8:30 - 16:45 | Fri: 8:30 - 15:30